Network Working Group K. Kompella Request for Comments: 3970 Juniper Networks Category: Standards Track January 2005 A Traffic Engineering (TE) MIB Status of This Memo This document specifies an Internet standards track protocol for the Internet community, and requests discussion and suggestions for improvements. Please refer to the current edition of the "Internet Official Protocol Standards" (STD 1) for the standardization state and status of this protocol. Distribution of this memo is unlimited. Copyright Notice Copyright (C) The Internet Society (2005). Abstract This memo defines a portion of the Management Information Base (MIB) for use with network management protocols in the Internet community. In particular, it describes managed objects for Traffic Engineered (TE) Tunnels; for example, Multi-Protocol Label Switched Paths. Table of Contents 1. Introduction . . . . . . . . . . . . . . . . . . . . . . . . . 2 1.1. Specification of Requirements. . . . . . . . . . . . . . 2 2. The Internet-Standard Management Framework . . . . . . . . . . 2 3. Overview of the MIB Module . . . . . . . . . . . . . . . . . . 2 3.1. Traffic Engineering Information. . . . . . . . . . . . . 3 3.2. Traffic Tunnel Information . . . . . . . . . . . . . . . 3 3.3. Path Information . . . . . . . . . . . . . . . . . . . . 3 3.4. Hop Information. . . . . . . . . . . . . . . . . . . . . 4 3.5. Relationship with Other MIB Modules. . . . . . . . . . . 4 4. Creating, Modifying, and Deleting a TE Tunnel. . . . . . . . . 4 5. MIB Specification. . . . . . . . . . . . . . . . . . . . . . . 5 6. References . . . . . . . . . . . . . . . . . . . . . . . . . . 40 6.1. Normative References . . . . . . . . . . . . . . . . . . 40 6.2. Informative References . . . . . . . . . . . . . . . . . 40 7. Security Considerations. . . . . . . . . . . . . . . . . . . . 41 Acknowledgments. . . . . . . . . . . . . . . . . . . . . . . . . . 42 Author's Address . . . . . . . . . . . . . . . . . . . . . . . . . 43 Full Copyright Statement . . . . . . . . . . . . . . . . . . . . . 44 Kompella Standards Track [Page 1] RFC 3970 A Traffic Engineering (TE) MIB January 2005 1. Introduction This memo defines a portion of the Management Information Base (MIB) for use with network management protocols in the Internet community. In particular, it describes managed objects for Traffic Engineered (TE) Tunnels; for example, Multi-Protocol Label Switched Paths ([7], [8]). The MIB module defined by this memo allows one to configure TE Tunnels, to assign one or more paths to a Tunnel, and to monitor operational aspects of the Tunnel, such as the number of octets and packets that have passed through the Tunnel. As it stands, this MIB module can only be used to configure or monitor a TE Tunnel at its ingress. The ingress is then expected to use some protocol (such as RSVP-TE) to signal the other routers in the path the information they need to set up the tunnel. The extension of this module for use at other points of a Tunnel is for further study. 1.1. Specification of Requirements The key words "MUST", "MUST NOT", "REQUIRED", "SHALL", "SHALL NOT", "SHOULD", "SHOULD NOT", "RECOMMENDED", "MAY", and "OPTIONAL" in this document are to be interpreted as described in RFC 2119 [1]. 2. The Internet-Standard Management Framework For a detailed overview of the documents that describe the current Internet-Standard Management Framework, please refer to Section 7 of RFC 3410 [8]. Managed objects are accessed via a virtual information store, termed the Management Information Base or MIB. MIB objects are generally accessed through the Simple Network Management Protocol (SNMP). Objects in the MIB are defined using the mechanisms defined in the Structure of Management Information (SMI). This memo specifies a MIB module that is compliant to the SMIv2, which is described in STD 58, RFC 2578 [2], STD 58, RFC 2579 [3] and STD 58, RFC 2580 [4]. 3. Overview of the MIB Module The Traffic Engineering MIB module consists of four parts: 1) Traffic Engineering information, 2) a table of Traffic Engineering Tunnels, 3) a table of Paths that tunnels take, and 4) a table of Hops that make up a tunnel path. The MIB module also has statements for minimal and full compliance. Kompella Standards Track [Page 2] RFC 3970 A Traffic Engineering (TE) MIB January 2005 The following subsections give an overview of each part. All objects are mandatory. For minimal compliance, all objects MAY be implemented read-only; for full compliance, all objects must be implemented to their stated MAX-ACCESS capabilities. Notifications are optional. 3.1. Traffic Engineering Information This part contains information about the Link State Protocols used to carry TE information, the signaling protocols used to set up Traffic Tunnels, the number of Traffic Tunnels that have been configured and that are operational, and a mapping of Administrative Group (called Resource Classes in [7]) numbers to names. 3.2. Traffic Tunnel Information This part contains a table of Traffic Tunnels and information about each one. This information includes the Tunnel name, its configuration information, its operational information, and the active path(s) that the Tunnel takes. Configuration information includes the end points of the Traffic Tunnel, and the number of configured paths for the Traffic Tunnel. Operational information includes the current state (up/down), the count of octets and packets sent on the Traffic Tunnel, how long it has been up, and how many state transitions the Traffic Tunnel has had. Operational path information includes the number of operational paths, the number of path changes, and when the last path change was. 3.3. Path Information A Tunnel is a logical entity. An instantiation of a Tunnel is one or more Paths; each Path has a route (also called Explicit Route) or sequence of hops. A Path is indexed by a dual index: The primary index is that of the Tunnel to which the Path belongs; the secondary index is that of the Path itself. The configured information for a Path consists of the constraints for the Path and a configured route. The operational information consists of the Path status, the computed route (i.e., the route that was computed to satisfy the constraints), and the actual path as recorded by the signaling protocol. Kompella Standards Track [Page 3] RFC 3970 A Traffic Engineering (TE) MIB January 2005 3.4. Hop Information A path consists of a sequence of hops. A hop can be loose (meaning that the path eventually traverses the specified node) or strict (meaning that the specified node and possibly the link must be the next node in the path). A hop can be specified as an IPv4 address, an IPv6 address, an Autonomous System number or an unnumbered interface index [5]. The Hop Table contains all hops for all paths on a given router. It is organized as follows. There is a primary index that identifies a list of hops and a secondary index that identifies individual hops. Thus, to get the sequence of recorded hops for a path, one looks up the path's tePathRecordedRoute, which is a primary index into the Hop Table. Then to get the list of actual hops in order for the recorded path, one uses a secondary index of 1, 2, .... 3.5. Relationship with Other MIB Modules A TE Tunnel can extend objects from two other MIB modules; one is the Interfaces MIB [10], and the other is the IP Tunnel MIB [11]. The mechanism for doing so is to assign the TE Tunnel index (teTunnelIndex) with a valid ifIndex value in ifTable. If a TE Tunnel is deemed an interface, a new interface object is created and assigned an ifIndex value in ifTable. Then a TE Tunnel object is created, setting teTunnelIndex to the same value as the interface index. If (and only if) a TE Tunnel is considered an interface, it may also be considered an IP tunnel (if the encapsulation of the TE Tunnel is IP). In that case, the interface associated with the TE Tunnel should have its ifType set to tunnel(131). If a TE Tunnel is not considered an interface, then the TE Tunnel index (teTunnelIndex) SHOULD be set to a value at least 2^24, so that it is distinct from normal interfaces. 4. Creating, Modifying, and Deleting a TE Tunnel To create a TE Tunnel, one first obtains a free Tunnel index by using the object teNextTunnelIndex. One then creates the Tunnel, including all parameters, either as createAndGo or createAndWait. Then, TE Paths for this Tunnel can be created by using the teTunnelNextPathIndex object, again as createAndGo or createAndWait. A particular Path is computed and signaled when both the Path and the enclosing Tunnel have RowStatus 'active'. Kompella Standards Track [Page 4] RFC 3970 A Traffic Engineering (TE) MIB January 2005 To build a Path's configured route, one first gets a free PathHop index by using teNextPathHopIndex, and then builds the route hop-by- hop using the secondary index, setting the AddrType, Address, and HopType for each Hop. Finally, one sets the tePathConfiguredRoute in the Path to the PathHop index obtained. Modifying certain properties of a TE Tunnel or a TE Path may require setting the RowStatus of the Tunnel (or Path) to 'notInService' before making the changes and then setting the RowStatus of the Tunnel (or Path) back to 'active' to re-signal all Paths of the Tunnel (or the modified Path). A TE Tunnel and all its Paths can be deleted by setting the Tunnel's RowStatus to 'destroy'. A specific Path within a Tunnel can be destroyed by setting that Path's RowStatus to 'destroy'. 5. MIB Specification This MIB module IMPORTs objects from RFCs 2578 [2], 2579 [3], 2580 [3], 3411 [6], and 3811 [5] and it also has REFERENCE clauses to RFCs 3209 [8] and 3212 [12]. TE-MIB DEFINITIONS ::= BEGIN IMPORTS MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE, mib-2, Integer32, Gauge32, Counter32, Counter64, Unsigned32, TimeTicks FROM SNMPv2-SMI RowStatus, StorageType, TimeStamp, TruthValue FROM SNMPv2-TC SnmpAdminString FROM SNMP-FRAMEWORK-MIB MODULE-COMPLIANCE, OBJECT-GROUP, NOTIFICATION-GROUP FROM SNMPv2-CONF TeHopAddress, TeHopAddressType, MplsBitRate FROM MPLS-TC-STD-MIB; teMIB MODULE-IDENTITY LAST-UPDATED "200501040000Z" -- 01 January 2005 ORGANIZATION "IETF Traffic Engineering Working Group" CONTACT-INFO " Editor: Kireeti Kompella Postal: Juniper Networks, Inc. 1194 Mathilda Ave Kompella Standards Track [Page 5] RFC 3970 A Traffic Engineering (TE) MIB January 2005 Sunnyvale, CA 94089 Tel: +1 408 745 2000 E-mail: kireeti@juniper.net The IETF Traffic Engineering Working Group is chaired by Jim Boyle and Ed Kern. WG Mailing List information: General Discussion: te-wg@ops.ietf.org To Subscribe: te-wg-request@ops.ietf.org In Body: subscribe Archive: ftp://ops.ietf.org/pub/lists Comments on the MIB module should be sent to the mailing list. The archives for this mailing list should be consulted for previous discussion on this MIB. " DESCRIPTION "The Traffic Engineering MIB module. Copyright (C) The Internet Society (2005). This version of this MIB module is part of RFC 3970; see the RFC itself for full legal notices. " -- revision history REVISION "200501040000Z" -- 01 January 2005 DESCRIPTION "Initial version, published as RFC 3970." ::= { mib-2 122 } -- Top level objects teMIBNotifications OBJECT IDENTIFIER ::= { teMIB 0 } teMIBObjects OBJECT IDENTIFIER ::= { teMIB 1 } teMIBConformance OBJECT IDENTIFIER ::= { teMIB 2 } -- **************************************************************** -- -- TE MIB Objects -- -- TE Info teInfo OBJECT IDENTIFIER ::= { teMIBObjects 1 } teDistProtocol OBJECT-TYPE Kompella Standards Track [Page 6] RFC 3970 A Traffic Engineering (TE) MIB January 2005 SYNTAX BITS { other(0), isis(1), ospf(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "IGP used to distribute Traffic Engineering information and topology to each device for the purpose of automatic path computation. More than one IGP may be used to distribute TE information. " ::= { teInfo 1 } teSignalingProto OBJECT-TYPE SYNTAX BITS { other(0), rsvpte(1), crldp(2), static(3) -- static configuration } MAX-ACCESS read-only STATUS current DESCRIPTION "Traffic Engineering signaling protocols supported by this device. More than one protocol may be supported. " REFERENCE "For a description of RSVP-TE, see RFC 3209; for CR-LDP, see RFC 3212. " ::= { teInfo 2 } teNotificationEnable OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "If this object is true, then it enables the generation of notifications from this MIB module. Otherwise notifications are not generated. " DEFVAL { false } ::= { teInfo 3 } teNextTunnelIndex OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "An integer that may be used as a new Index in the Kompella Standards Track [Page 7] RFC 3970 A Traffic Engineering (TE) MIB January 2005 teTunnelTable. The special value of 0 indicates that no more new entries can be created in that table. When this MIB module is used for configuration, this object always contains a legal value (if non-zero) for an index that is not currently used in that table. The Command Generator (Network Management Application) reads this variable and uses the (non-zero) value read when creating a new row with an SNMP SET. When the SET is performed, the Command Responder (agent) must determine whether the value is indeed still unused; Two Network Management Applications may attempt to create a row (configuration entry) simultaneously and use the same value. If it is currently unused, the SET succeeds, and the Command Responder (agent) changes the value of this object according to an implementation-specific algorithm. If the value is in use, however, the SET fails. The Network Management Application must then re-read this variable to obtain a new usable value. " ::= { teInfo 4 } teNextPathHopIndex OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "An integer that may be used as a new Index in the tePathHopTable. The special value of 0 indicates that no more new entries can be created in that table. When this MIB module is used for configuration, this object always contains a legal value (if non-zero) for an index that is not currently used in that table. The Command Generator (Network Management Application) reads this variable and uses the (non-zero) value read when creating a new row with an SNMP SET. When the SET is performed, the Command Responder (agent) must determine whether the value is indeed still unused; Two Network Management Applications may attempt to create a row (configuration entry) simultaneously and use the same value. If it is currently unused, the SET Kompella Standards Track [Page 8] RFC 3970 A Traffic Engineering (TE) MIB January 2005 succeeds, and the Command Responder (agent) changes the value of this object according to an implementation-specific algorithm. If the value is in use, however, the SET fails. The Network Management Application must then re-read this variable to obtain a new usable value. " ::= { teInfo 5 } teConfiguredTunnels OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of currently configured Tunnels." ::= { teInfo 6 } teActiveTunnels OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of currently active Tunnels." ::= { teInfo 7 } tePrimaryTunnels OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of currently active Tunnels running on their primary paths. " ::= { teInfo 8 } teAdminGroupTable OBJECT-TYPE SYNTAX SEQUENCE OF TeAdminGroupEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A mapping of configured administrative groups. Each entry represents an Administrative Group and provides a name and index for the group. Administrative groups are used to label links in the Traffic Engineering topology in order to place constraints (include and exclude) on Tunnel paths. A groupName can only be linked to one group number. The groupNumber is the number assigned to the administrative group used in constraints, such as tePathIncludeAny or tePathIncludeAll. " Kompella Standards Track [Page 9] RFC 3970 A Traffic Engineering (TE) MIB January 2005 ::= { teInfo 9 } teAdminGroupEntry OBJECT-TYPE SYNTAX TeAdminGroupEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A mapping between a configured group number and its human-readable name. The group number should be between 1 and 32, inclusive. Group number n represents bit number (n-1) in the bit vector for Include/Exclude constraints. All entries in this table MUST be kept in stable storage so that they will re-appear in case of a restart/reboot. " INDEX { teAdminGroupNumber } ::= { teAdminGroupTable 1 } TeAdminGroupEntry ::= SEQUENCE { teAdminGroupNumber Integer32, teAdminGroupName SnmpAdminString, teAdminGroupRowStatus RowStatus } teAdminGroupNumber OBJECT-TYPE SYNTAX Integer32 (1..32) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Index of the administrative group." ::= { teAdminGroupEntry 1 } teAdminGroupName OBJECT-TYPE SYNTAX SnmpAdminString (SIZE (1..32)) MAX-ACCESS read-create STATUS current DESCRIPTION "Name of the administrative group." ::= { teAdminGroupEntry 2 } teAdminGroupRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "The status of this conceptual row. The value of this object has no effect on whether other objects in this conceptual row can be Kompella Standards Track [Page 10] RFC 3970 A Traffic Engineering (TE) MIB January 2005 modified. " ::= { teAdminGroupEntry 3 } -- Tunnel Table teTunnelTable OBJECT-TYPE SYNTAX SEQUENCE OF TeTunnelEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table of Configured Traffic Tunnels." ::= { teMIBObjects 2 } teTunnelEntry OBJECT-TYPE SYNTAX TeTunnelEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry containing information about a particular Traffic Tunnel. " INDEX { teTunnelIndex } ::= { teTunnelTable 1 } TeTunnelEntry ::= SEQUENCE { teTunnelIndex Unsigned32, teTunnelName SnmpAdminString, teTunnelNextPathIndex Unsigned32, -- Conceptual row information: teTunnelRowStatus RowStatus, teTunnelStorageType StorageType, -- Address information: teTunnelSourceAddressType TeHopAddressType, teTunnelSourceAddress TeHopAddress, teTunnelDestinationAddressType TeHopAddressType, teTunnelDestinationAddress TeHopAddress, -- State/performance information: teTunnelState INTEGER, teTunnelDiscontinuityTimer TimeStamp, teTunnelOctets Counter64, teTunnelPackets Counter64, teTunnelLPOctets Counter32, teTunnelLPPackets Counter32, teTunnelAge TimeTicks, teTunnelTimeUp TimeTicks, teTunnelPrimaryTimeUp TimeTicks, teTunnelTransitions Counter32, teTunnelLastTransition TimeTicks, Kompella Standards Track [Page 11] RFC 3970 A Traffic Engineering (TE) MIB January 2005 teTunnelPathChanges Counter32, teTunnelLastPathChange TimeTicks, teTunnelConfiguredPaths Gauge32, teTunnelStandbyPaths Gauge32, teTunnelOperationalPaths Gauge32 } teTunnelIndex OBJECT-TYPE SYNTAX Unsigned32 (1..4294967295) MAX-ACCESS not-accessible STATUS current DESCRIPTION "A unique index that identifies a Tunnel. If the TE Tunnel is considered an interface, then this index must match the interface index of the corresponding interface. Otherwise, this index must be at least 2^24, so that it does not overlap with any existing interface index. " ::= { teTunnelEntry 1 } teTunnelName OBJECT-TYPE SYNTAX SnmpAdminString (SIZE (1..32)) MAX-ACCESS read-create STATUS current DESCRIPTION "Name of the Traffic Tunnel. Note that the name of a Tunnel MUST be unique. When a SET request contains a name that is already in use for another entry, then the implementation must return an inconsistentValue error. The value of this object cannot be changed if the if the value of the corresponding teTunnelRowStatus object is 'active'. " ::= { teTunnelEntry 2 } teTunnelNextPathIndex OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "An integer that may be used as a new Index for the next Path in this Tunnel. The special value of 0 indicates that no more Paths can be created for this Tunnel, or that no more new entries can be created in tePathTable. Kompella Standards Track [Page 12] RFC 3970 A Traffic Engineering (TE) MIB January 2005 When this MIB module is used for configuration, this object always contains a legal value (if non-zero) for an index that is not currently used in that table. The Command Generator (Network Management Application) reads this variable and uses the (non-zero) value read when creating a new row with an SNMP SET. When the SET is performed, the Command Responder (agent) must determine whether the value is indeed still unused; Two Network Management Applications may attempt to create a row (configuration entry) simultaneously and use the same value. If it is currently unused, the SET succeeds, and the Command Responder (agent) changes the value of this object according to an implementation-specific algorithm. If the value is in use, however, the SET fails. The Network Management Application must then re-read this variable to obtain a new usable value. " ::= { teTunnelEntry 3 } teTunnelRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "The status of this conceptual row. When the value of this object is 'active', then the values for the corresponding objects teTunnelName, teTunnelSourceAddressType, teTunnelSourceAddress, teTunnelDestinationAddressType, and teTunnelDestinationAddress cannot be changed. " ::= { teTunnelEntry 4 } teTunnelStorageType OBJECT-TYPE SYNTAX StorageType MAX-ACCESS read-create STATUS current DESCRIPTION "The storage type for this conceptual row. Conceptual rows having the value 'permanent' need not allow write-access to any columnar objects in the row. " ::= { teTunnelEntry 5 } Kompella Standards Track [Page 13] RFC 3970 A Traffic Engineering (TE) MIB January 2005 teTunnelSourceAddressType OBJECT-TYPE SYNTAX TeHopAddressType MAX-ACCESS read-create STATUS current DESCRIPTION "The type of Traffic Engineered Tunnel hop address for the source of this Tunnel. Typically, this address type is IPv4 or IPv6, with a prefix length of 32 or 128, respectively. If the TE Tunnel path is being computed by a path computation server, however, it is possible to use more flexible source address types, such as AS numbers or prefix lengths less than host address lengths. The value of this object cannot be changed if the value of the corresponding teTunnelRowStatus object is 'active'. " ::= { teTunnelEntry 6 } teTunnelSourceAddress OBJECT-TYPE SYNTAX TeHopAddress MAX-ACCESS read-create STATUS current DESCRIPTION "The Source Traffic Engineered Tunnel hop address of this Tunnel. The type of this address is determined by the value of the corresponding teTunnelSourceAddressType. Note that the source and destination addresses of a Tunnel can be different address types. The value of this object cannot be changed if the value of the corresponding teTunnelRowStatus object is 'active'. " ::= { teTunnelEntry 7 } teTunnelDestinationAddressType OBJECT-TYPE SYNTAX TeHopAddressType MAX-ACCESS read-create STATUS current DESCRIPTION "The type of Traffic Engineered Tunnel hop address for the destination of this Tunnel. The value of this object cannot be changed if the value of the corresponding teTunnelRowStatus object is 'active'. Kompella Standards Track [Page 14] RFC 3970 A Traffic Engineering (TE) MIB January 2005 " ::= { teTunnelEntry 8 } teTunnelDestinationAddress OBJECT-TYPE SYNTAX TeHopAddress MAX-ACCESS read-create STATUS current DESCRIPTION "The Destination Traffic Engineered Tunnel hop address of this Tunnel. The type of this address is determined by the value of the corresponding teTunnelDestinationAddressType. Note that source and destination addresses of a Tunnel can be different address types. The value of this object cannot be changed if the value of the corresponding teTunnelRowStatus object is 'active'. " ::= { teTunnelEntry 9 } teTunnelState OBJECT-TYPE SYNTAX INTEGER { unknown(1), up(2), down(3), testing(4) } MAX-ACCESS read-only STATUS current DESCRIPTION "The operational state of the Tunnel." ::= { teTunnelEntry 10 } teTunnelDiscontinuityTimer OBJECT-TYPE SYNTAX TimeStamp MAX-ACCESS read-only STATUS current DESCRIPTION "The value of sysUpTime on the most recent occasion at which any one or more of this tunnel's counters suffered a discontinuity. The relevant counters are teTunnelOctets, teTunnelPackets, teTunnelLPOctets, and teTunnelLPPackets. If no such discontinuities have occurred since the last re-initialization of the local management subsystem then this object contains a zero value. " ::= { teTunnelEntry 11 } Kompella Standards Track [Page 15] RFC 3970 A Traffic Engineering (TE) MIB January 2005 teTunnelOctets OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of octets that have been forwarded over the Tunnel. Discontinuities in the value of this counter can occur at re-initialization of the management system, and at other times, as indicated by the value of teTunnelDiscontinuityTimer. " ::= { teTunnelEntry 12 } teTunnelPackets OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of packets that have been forwarded over the Tunnel. Discontinuities in the value of this counter can occur at re-initialization of the management system and at other times, as indicated by the value of teTunnelDiscontinuityTimer. " ::= { teTunnelEntry 13 } teTunnelLPOctets OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of octets that have been forwarded over the Tunnel. Discontinuities in the value of this counter can occur at re-initialization of the management system and at other times, as indicated by the value of teTunnelDiscontinuityTimer. " ::= { teTunnelEntry 14 } teTunnelLPPackets OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of packets that have been forwarded over the Tunnel. Kompella Standards Track [Page 16] RFC 3970 A Traffic Engineering (TE) MIB January 2005 Discontinuities in the value of this counter can occur at re-initialization of the management system and at other times, as indicated by the value of teTunnelDiscontinuityTimer. " ::= { teTunnelEntry 15 } teTunnelAge OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-only STATUS current DESCRIPTION "The age (i.e., time from creation of this conceptual row till now) of this Tunnel in hundredths of a second. Note that because TimeTicks wrap in about 16 months, this value is best used in interval measurements. " ::= { teTunnelEntry 16 } teTunnelTimeUp OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-only STATUS current DESCRIPTION "The total time in hundredths of a second that this Tunnel has been operational. Note that because TimeTicks wrap in about 16 months, this value is best used in interval measurements. An example of usage of this object would be to compute the percentage up time over a period of time by obtaining values of teTunnelAge and teTunnelTimeUp at two points in time and computing the following ratio: ((teTunnelTimeUp2 - teTunnelTimeUp1)/ (teTunnelAge2 - teTunnelAge1)) * 100 %. In doing so, the management station must account for wrapping of the values of teTunnelAge and teTunnelTimeUp between the two measurements. " ::= { teTunnelEntry 17 } teTunnelPrimaryTimeUp OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-only STATUS current DESCRIPTION "The total time in hundredths of a second that this Tunnel's primary path has been operational. Note that because TimeTicks wrap in about 16 months, this Kompella Standards Track [Page 17] RFC 3970 A Traffic Engineering (TE) MIB January 2005 value is best used in interval measurements. An example of usage of this field would be to compute what percentage of time that a TE Tunnel was on the primary path over a period of time by computing ((teTunnelPrimaryTimeUp2 - teTunnelPrimaryTimeUp1)/ (teTunnelTimeUp2 - teTunnelTimeUp1))*100 %. In doing so, the management station must account for wrapping of the values of teTunnelPrimaryTimeUp and teTunnelTimeUp between the two measurements. " ::= { teTunnelEntry 18 } teTunnelTransitions OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of operational state transitions (up -> down and down -> up) this Tunnel has undergone. " ::= { teTunnelEntry 19 } teTunnelLastTransition OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-only STATUS current DESCRIPTION "The time in hundredths of a second since the last operational state transition occurred on this Tunnel. Note that if the last transition was over 16 months ago, this value will be inaccurate. " ::= { teTunnelEntry 20 } teTunnelPathChanges OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of path changes this Tunnel has had." ::= { teTunnelEntry 21 } teTunnelLastPathChange OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-only STATUS current Kompella Standards Track [Page 18] RFC 3970 A Traffic Engineering (TE) MIB January 2005 DESCRIPTION "The time in hundredths of a second since the last path change occurred on this Tunnel. Note that if the last transition was over 16 months ago, this value will be inaccurate. Path changes may be caused by network events or by reconfiguration that affects the path. " ::= { teTunnelEntry 22 } teTunnelConfiguredPaths OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of paths configured for this Tunnel." ::= { teTunnelEntry 23 } teTunnelStandbyPaths OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of standby paths configured for this Tunnel. " ::= { teTunnelEntry 24 } teTunnelOperationalPaths OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of operational paths for this Tunnel. This includes the path currently active, as well as operational standby paths. " ::= { teTunnelEntry 25 } -- **************************************************************** -- -- Tunnel Path Table -- tePathTable OBJECT-TYPE SYNTAX SEQUENCE OF TePathEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table of Configured Traffic Tunnels." ::= { teMIBObjects 3 } Kompella Standards Track [Page 19] RFC 3970 A Traffic Engineering (TE) MIB January 2005 tePathEntry OBJECT-TYPE SYNTAX TePathEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry containing information about a particular Traffic Tunnel. Each Traffic Tunnel can have zero or more Traffic Paths. As a Traffic Path can only exist over an existing Traffic Tunnel, all tePathEntries with a value of n for teTunnelIndex MUST be removed by the implementation when the corresponding teTunnelEntry with a value of n for teTunnelIndex is removed. " INDEX { teTunnelIndex, tePathIndex } ::= { tePathTable 1 } TePathEntry ::= SEQUENCE { tePathIndex Unsigned32, tePathName SnmpAdminString, -- Conceptual row information tePathRowStatus RowStatus, tePathStorageType StorageType, -- Path properties tePathType INTEGER, tePathConfiguredRoute Unsigned32, tePathBandwidth MplsBitRate, tePathIncludeAny Unsigned32, tePathIncludeAll Unsigned32, tePathExclude Unsigned32, tePathSetupPriority Integer32, tePathHoldPriority Integer32, tePathProperties BITS, -- Path status tePathOperStatus INTEGER, tePathAdminStatus INTEGER, tePathComputedRoute Unsigned32, tePathRecordedRoute Unsigned32 } tePathIndex OBJECT-TYPE SYNTAX Unsigned32 (1..4294967295) MAX-ACCESS not-accessible STATUS current DESCRIPTION "An index that uniquely identifies a path within a Tunnel. Kompella Standards Track [Page 20] RFC 3970 A Traffic Engineering (TE) MIB January 2005 The combination ofthus uniquely identifies a path among all paths on this router. " ::= { tePathEntry 1 } tePathName OBJECT-TYPE SYNTAX SnmpAdminString (SIZE(0..32)) MAX-ACCESS read-create STATUS current DESCRIPTION "The name of this path. A pathName must be unique within the set of paths over a single tunnel. If a SET request is received with a duplicate name, then the implementation MUST return an inconsistentValue error. The value of this object cannot be changed if the value of the corresponding teTunnelRowStatus object is 'active'. " ::= { tePathEntry 2 } tePathRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "The status of this conceptual row. When the value of this object is 'active', then the value of tePathName cannot be changed. All other writable objects may be changed; however, these changes may affect traffic going over the TE tunnel or require the path to be computed and/or re-signaled. " ::= { tePathEntry 3 } tePathStorageType OBJECT-TYPE SYNTAX StorageType MAX-ACCESS read-create STATUS current DESCRIPTION "The storage type for this conceptual row. Conceptual rows having the value 'permanent' need not allow write-access to any columnar objects in the row. " Kompella Standards Track [Page 21] RFC 3970 A Traffic Engineering (TE) MIB January 2005 ::= { tePathEntry 4 } tePathType OBJECT-TYPE SYNTAX INTEGER { other(1), primary(2), standby(3), secondary(4) } MAX-ACCESS read-create STATUS current DESCRIPTION "The type for this PathEntry; i.e., whether this path is a primary path, a standby path, or a secondary path. " ::= { tePathEntry 5 } tePathConfiguredRoute OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-create STATUS current DESCRIPTION "The route that this TE path is configured to follow; i.e., an ordered list of hops. The value of this object gives the primary index into the Hop Table. The secondary index is the hop count in the path, so to get the route, one could get the first hop with index in the Hop Table and do a getnext to get subsequent hops. " ::= { tePathEntry 6 } tePathBandwidth OBJECT-TYPE SYNTAX MplsBitRate UNITS "Kilobits per second" MAX-ACCESS read-create STATUS current DESCRIPTION "The configured bandwidth for this Tunnel, in units of thousands of bits per second (Kbps). " DEFVAL { 0 } ::= { tePathEntry 7 } tePathIncludeAny OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-create STATUS current DESCRIPTION "This is a configured set of administrative groups specified as a bit vector (i.e., bit n is 1 if group Kompella Standards Track [Page 22] RFC 3970 A Traffic Engineering (TE) MIB January 2005 n is in the set, where n = 0 is the LSB). For each link that this path goes through, the link must have at least one of the groups specified in IncludeAny to be acceptable. If IncludeAny is zero, all links are acceptable. " DEFVAL { 0 } ::= { tePathEntry 8 } tePathIncludeAll OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-create STATUS current DESCRIPTION "This is a configured set of administrative groups specified as a bit vector (i.e., bit n is 1 if group n is in the set, where n = 0 is the LSB). For each link that this path goes through, the link must have all of the groups specified in IncludeAll to be acceptable. If IncludeAll is zero, all links are acceptable. " DEFVAL { 0 } ::= { tePathEntry 9 } tePathExclude OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-create STATUS current DESCRIPTION "This is a configured set of administrative groups specified as a bit vector (i.e., bit n is 1 if group n is in the set, where n = 0 is the LSB). For each link that this path goes through, the link MUST have groups associated with it, and the intersection of the link's groups and the 'exclude' set MUST be null. " DEFVAL { 0 } ::= { tePathEntry 10 } tePathSetupPriority OBJECT-TYPE SYNTAX Integer32 (0..7) MAX-ACCESS read-create STATUS current DESCRIPTION "The setup priority configured for this path, with 0 as the highest priority and 7 as the lowest. " DEFVAL { 7 } Kompella Standards Track [Page 23] RFC 3970 A Traffic Engineering (TE) MIB January 2005 ::= { tePathEntry 11 } tePathHoldPriority OBJECT-TYPE SYNTAX Integer32 (0..7) MAX-ACCESS read-create STATUS current DESCRIPTION "The hold priority configured for this path, with 0 as the highest priority and 7 as the lowest. " DEFVAL { 0 } ::= { tePathEntry 12 } tePathProperties OBJECT-TYPE SYNTAX BITS { recordRoute(0), cspf(1), makeBeforeBreak(2), mergeable(3), fastReroute(4), protected(5) } MAX-ACCESS read-create STATUS current DESCRIPTION "The set of configured properties for this path, expressed as a bit map. For example, if the path supports 'make before break', then bit 2 is set. " ::= { tePathEntry 13 } tePathOperStatus OBJECT-TYPE SYNTAX INTEGER { unknown(0), down(1), testing(2), dormant(3), ready(4), operational(5) } MAX-ACCESS read-only STATUS current DESCRIPTION "The operational status of the path: unknown: down: Signaling failed. testing: Administratively set aside for testing. dormant: Not signaled (for a backup tunnel). ready: Signaled but not yet carrying traffic. operational: Signaled and carrying traffic. " Kompella Standards Track [Page 24] RFC 3970 A Traffic Engineering (TE) MIB January 2005 ::= { tePathEntry 14 } tePathAdminStatus OBJECT-TYPE SYNTAX INTEGER { normal(1), testing(2) } MAX-ACCESS read-create STATUS current DESCRIPTION "The operational status of the path: normal: Used normally for forwarding. testing: Administratively set aside for testing. " ::= { tePathEntry 15 } tePathComputedRoute OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "The route computed for this path, perhaps using some form of Constraint-based Routing. The algorithm is implementation dependent. This object returns the computed route as an ordered list of hops. The value of this object gives the primary index into the Hop Table. The secondary index is the hop count in the path, so to get the route, one could get the first hop with index in the Hop Table and do a getnext to get subsequent hops. A value of zero (0) means there is no computedRoute. " ::= { tePathEntry 16 } tePathRecordedRoute OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "The route actually used for this path, as recorded by the signaling protocol. This is again an ordered list of hops; each hop is expected to be strict. The value of this object gives the primary index into the Hop Table. The secondary index is the hop count in the path, so to get the route, one can get the first hop with index in the Hop Table and do a getnext to get subsequent Kompella Standards Track [Page 25] RFC 3970 A Traffic Engineering (TE) MIB January 2005 hops. A value of zero (0) means there is no recordedRoute. " ::= { tePathEntry 17 } -- **************************************************************** -- -- Tunnel Path Hop Table -- tePathHopTable OBJECT-TYPE SYNTAX SEQUENCE OF TePathHopEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table of Tunnel Path Hops." ::= { teMIBObjects 4 } tePathHopEntry OBJECT-TYPE SYNTAX TePathHopEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry containing information about a particular hop. " INDEX { teHopListIndex, tePathHopIndex } ::= { tePathHopTable 1 } TePathHopEntry ::= SEQUENCE { teHopListIndex Unsigned32, tePathHopIndex Unsigned32, -- Conceptual row information tePathHopRowStatus RowStatus, tePathHopStorageType StorageType, tePathHopAddrType TeHopAddressType, tePathHopAddress TeHopAddress, tePathHopType INTEGER } teHopListIndex OBJECT-TYPE SYNTAX Unsigned32 (1..4294967295) MAX-ACCESS not-accessible STATUS current DESCRIPTION "An index that identifies a list of hops. This is the primary index to access hops. " ::= { tePathHopEntry 1 } Kompella Standards Track [Page 26] RFC 3970 A Traffic Engineering (TE) MIB January 2005 tePathHopIndex OBJECT-TYPE SYNTAX Unsigned32 (1..4294967295) MAX-ACCESS not-accessible STATUS current DESCRIPTION "An index that identifies a particular hop among the list of hops for a path. An index of i identifies the ith hop. This is the secondary index for a hop entry. " ::= { tePathHopEntry 2 } tePathHopRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "The status of this conceptual row. Any field in this table can be changed, even if the value of this object is 'active'. However, such a change may cause traffic to be rerouted or even disrupted. " ::= { tePathHopEntry 3 } tePathHopStorageType OBJECT-TYPE SYNTAX StorageType MAX-ACCESS read-create STATUS current DESCRIPTION "The storage type for this conceptual row. Conceptual rows having the value 'permanent' need not allow write-access to any columnar objects in the row. " ::= { tePathHopEntry 4 } tePathHopAddrType OBJECT-TYPE SYNTAX TeHopAddressType MAX-ACCESS read-create STATUS current DESCRIPTION "The type of Traffic Engineered Tunnel hop Address of this hop. The value of this object cannot be changed if the value of the corresponding tePathRowStatus object is 'active'. " ::= { tePathHopEntry 5 } Kompella Standards Track [Page 27] RFC 3970 A Traffic Engineering (TE) MIB January 2005 tePathHopAddress OBJECT-TYPE SYNTAX TeHopAddress MAX-ACCESS read-create STATUS current DESCRIPTION "The Traffic Engineered Tunnel hop Address of this hop. The type of this address is determined by the value of the corresponding tePathHopAddressType. The value of this object cannot be changed if the value of the corresponding teTunnelRowStatus object is 'active'. " ::= { tePathHopEntry 6 } tePathHopType OBJECT-TYPE SYNTAX INTEGER { unknown(0), loose(1), strict(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "The type of hop: unknown: loose: This hop is a LOOSE hop. strict: This hop is a STRICT hop. " ::= { tePathHopEntry 7 } -- **************************************************************** -- -- TE Notifications -- teTunnelUp NOTIFICATION-TYPE OBJECTS { teTunnelName, tePathName } -- TunnelPath STATUS current DESCRIPTION "A teTunnelUp notification is generated when the Tunnel indexed by teTunnelName transitions to the 'up' state. A tunnel is up when at least one of its paths is up. The tePathName is the name of the path whose transition to up made the tunnel go up. Kompella Standards Track [Page 28] RFC 3970 A Traffic Engineering (TE) MIB January 2005 This notification MUST be limited to at most one every minute, in case the tunnel flaps up and down. " ::= { teMIBNotifications 1 } teTunnelDown NOTIFICATION-TYPE OBJECTS { teTunnelName, tePathName } -- TunnelPath STATUS current DESCRIPTION "A teTunnelDown notification is generated when the Tunnel indexed by teTunnelName transitions to the 'down' state. A tunnel is up when at least one of its paths is up. The tePathName is the name of the path whose transition to down made the tunnel go down. This notification MUST be limited to at most one every minute, in case the tunnel flaps up and down. " ::= { teMIBNotifications 2 } teTunnelChanged NOTIFICATION-TYPE OBJECTS { teTunnelName, tePathName } -- toTunnelPath STATUS current DESCRIPTION "A teTunnelChanged notification is generated when an active path on the Tunnel indexed by teTunnelName changes or a new path becomes active. The value of tePathName is the new active path. This notification MUST be limited to at most one every minute, in case the tunnel changes quickly. " ::= { teMIBNotifications 3 } teTunnelRerouted NOTIFICATION-TYPE OBJECTS { teTunnelName, tePathName } -- toTunnelPath STATUS current DESCRIPTION "A teTunnelRerouted notification is generated when an active path for the Tunnel indexed by teTunnelName stays the same, but its route changes. This notification MUST be limited to at most one every minute, in case the tunnel reroutes quickly. " ::= { teMIBNotifications 4 } Kompella Standards Track [Page 29] RFC 3970 A Traffic Engineering (TE) MIB January 2005 -- End of TE-MIB objects -- **************************************************************** -- -- TE Compliance Statements -- teGroups OBJECT IDENTIFIER ::= { teMIBConformance 1 } teModuleCompliance OBJECT IDENTIFIER ::= { teMIBConformance 2 } -- **************************************************************** -- -- TE object groups -- teTrafficEngineeringGroup OBJECT-GROUP OBJECTS { teTunnelName, teTunnelNextPathIndex, teTunnelRowStatus, teTunnelStorageType, teTunnelSourceAddressType, teTunnelSourceAddress, teTunnelDestinationAddressType, teTunnelDestinationAddress, teTunnelState, teTunnelDiscontinuityTimer, teTunnelOctets, teTunnelPackets, teTunnelLPOctets, teTunnelLPPackets, teTunnelAge, teTunnelTimeUp, teTunnelPrimaryTimeUp, teTunnelTransitions, teTunnelLastTransition, teTunnelPathChanges, teTunnelLastPathChange, teTunnelConfiguredPaths, teTunnelStandbyPaths, teTunnelOperationalPaths, tePathBandwidth, tePathIncludeAny, tePathIncludeAll, tePathExclude, Kompella Standards Track [Page 30] RFC 3970 A Traffic Engineering (TE) MIB January 2005 tePathSetupPriority, tePathHoldPriority, tePathProperties, tePathOperStatus, tePathAdminStatus, tePathComputedRoute, tePathRecordedRoute, teDistProtocol, teSignalingProto, teNotificationEnable, teNextTunnelIndex, teNextPathHopIndex, teAdminGroupName, teAdminGroupRowStatus, teConfiguredTunnels, teActiveTunnels, tePrimaryTunnels, tePathName, tePathType, tePathRowStatus, tePathStorageType, tePathConfiguredRoute, tePathHopRowStatus, tePathHopStorageType, tePathHopAddrType, tePathHopAddress, tePathHopType } STATUS current DESCRIPTION "Objects for Traffic Engineering in this MIB module." ::= { teGroups 1 } teNotificationGroup NOTIFICATION-GROUP NOTIFICATIONS { teTunnelUp, teTunnelDown, teTunnelChanged, teTunnelRerouted } STATUS current DESCRIPTION "Notifications specified in this MIB module." ::= { teGroups 2 } -- **************************************************************** -- -- TE compliance statements -- -- There are four compliance statements: read-only and full Kompella Standards Track [Page 31] RFC 3970 A Traffic Engineering (TE) MIB January 2005 -- compliance for regular TE devices, and read-only and full -- compliance for path computation servers. -- teModuleReadOnlyCompliance MODULE-COMPLIANCE STATUS current DESCRIPTION "When this MIB module is implemented without support for read-create (i.e., in read-only mode), then such an implementation can claim read-only compliance. Such a device can be monitored but cannot be configured with this MIB module. " MODULE -- enclosing module, i.e., TE-MIB MANDATORY-GROUPS { teTrafficEngineeringGroup } GROUP teNotificationGroup DESCRIPTION "Implementation of this group is optional." OBJECT teNotificationEnable MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT teAdminGroupName MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT teAdminGroupRowStatus SYNTAX RowStatus { active(1) } MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT teTunnelName MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT teTunnelRowStatus SYNTAX RowStatus { active(1) } MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT teTunnelStorageType MIN-ACCESS read-only DESCRIPTION "Write access is not required." Kompella Standards Track [Page 32] RFC 3970 A Traffic Engineering (TE) MIB January 2005 OBJECT teTunnelSourceAddressType SYNTAX TeHopAddressType { ipv4(1), ipv6(2) } MIN-ACCESS read-only DESCRIPTION "Write access is not required. An implementation is only required to support IPv4 and IPv6 host addresses." OBJECT teTunnelSourceAddress MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT teTunnelDestinationAddressType MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT teTunnelDestinationAddress MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT tePathName MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT tePathRowStatus SYNTAX RowStatus { active(1) } MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT tePathStorageType MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT tePathType MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT tePathConfiguredRoute MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT tePathBandwidth MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT tePathIncludeAny MIN-ACCESS read-only DESCRIPTION "Write access is not required." Kompella Standards Track [Page 33] RFC 3970 A Traffic Engineering (TE) MIB January 2005 OBJECT tePathIncludeAll MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT tePathExclude MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT tePathSetupPriority MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT tePathHoldPriority MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT tePathProperties MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT tePathAdminStatus MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT tePathHopRowStatus SYNTAX RowStatus { active(1) } MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT tePathHopStorageType MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT tePathHopAddrType MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT tePathHopAddress MIN-ACCESS read-only DESCRIPTION "Write access is not required." ::= { teModuleCompliance 1 } teModuleFullCompliance MODULE-COMPLIANCE STATUS current DESCRIPTION "When this MIB module is implemented with support for read-create, then the implementation can claim full compliance. Such devices can be both Kompella Standards Track [Page 34] RFC 3970 A Traffic Engineering (TE) MIB January 2005 monitored and configured with this MIB module. " MODULE -- enclosing module, i.e., TE-MIB MANDATORY-GROUPS { teTrafficEngineeringGroup } GROUP teNotificationGroup DESCRIPTION "Implementation of this group is optional." OBJECT teAdminGroupRowStatus SYNTAX RowStatus { active(1) } WRITE-SYNTAX RowStatus { createAndGo(4), destroy(6) } DESCRIPTION "Support for notInService, createAndWait and notReady is not required. " OBJECT teTunnelRowStatus SYNTAX RowStatus { active(1), notInService(2) } WRITE-SYNTAX RowStatus { active(1), notInService(2), createAndGo(4), destroy(6) } DESCRIPTION "Support for createAndWait and notReady is not required. " OBJECT teTunnelSourceAddressType SYNTAX TeHopAddressType { ipv4(1), ipv6(2) } DESCRIPTION "Write access is required. An implementation is only required to support IPv4 and IPv6 host addresses. " OBJECT tePathRowStatus SYNTAX RowStatus { active(1), notInService(2) } WRITE-SYNTAX RowStatus { active(1), notInService(2), createAndGo(4), destroy(6) } DESCRIPTION "Support for createAndWait and notReady is not required. " OBJECT tePathHopRowStatus SYNTAX RowStatus { active(1), notInService(2) } WRITE-SYNTAX RowStatus { active(1), notInService(2), Kompella Standards Track [Page 35] RFC 3970 A Traffic Engineering (TE) MIB January 2005 createAndGo(4), destroy(6) } DESCRIPTION "Support for createAndWait and notReady is not required. " ::= { teModuleCompliance 2 } teModuleServerReadOnlyCompliance MODULE-COMPLIANCE STATUS current DESCRIPTION "When this MIB module is implemented by a path computation server without support for read-create (i.e., in read-only mode), then the implementation can claim read-only compliance. Such a device can be monitored but cannot be configured with this MIB module. " MODULE -- enclosing module, i.e., TE-MIB MANDATORY-GROUPS { teTrafficEngineeringGroup } GROUP teNotificationGroup DESCRIPTION "Implementation of this group is optional." OBJECT teNotificationEnable MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT teAdminGroupName MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT teAdminGroupRowStatus SYNTAX RowStatus { active(1) } MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT teTunnelName MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT teTunnelRowStatus SYNTAX RowStatus { active(1) } MIN-ACCESS read-only DESCRIPTION "Write access is not required." Kompella Standards Track [Page 36] RFC 3970 A Traffic Engineering (TE) MIB January 2005 OBJECT teTunnelStorageType MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT teTunnelSourceAddressType MIN-ACCESS read-only DESCRIPTION "Write access is not required. A path computation server SHOULD implement all types of tunnel source address types. " OBJECT teTunnelSourceAddress MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT teTunnelDestinationAddressType MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT teTunnelDestinationAddress MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT tePathName MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT tePathRowStatus SYNTAX RowStatus { active(1) } MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT tePathStorageType MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT tePathType MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT tePathConfiguredRoute MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT tePathBandwidth MIN-ACCESS read-only DESCRIPTION "Write access is not required." Kompella Standards Track [Page 37] RFC 3970 A Traffic Engineering (TE) MIB January 2005 OBJECT tePathIncludeAny MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT tePathIncludeAll MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT tePathExclude MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT tePathSetupPriority MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT tePathHoldPriority MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT tePathProperties MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT tePathAdminStatus MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT tePathHopRowStatus SYNTAX RowStatus { active(1) } MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT tePathHopStorageType MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT tePathHopAddrType MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT tePathHopAddress MIN-ACCESS read-only DESCRIPTION "Write access is not required." ::= { teModuleCompliance 3 } teModuleServerFullCompliance MODULE-COMPLIANCE Kompella Standards Track [Page 38] RFC 3970 A Traffic Engineering (TE) MIB January 2005 STATUS current DESCRIPTION "When this MIB module is implemented by a path computation server with support for read-create, then the implementation can claim full compliance. " MODULE -- enclosing module, i.e., TE-MIB MANDATORY-GROUPS { teTrafficEngineeringGroup } GROUP teNotificationGroup DESCRIPTION "Implementation of this group is optional." OBJECT teAdminGroupRowStatus SYNTAX RowStatus { active(1) } WRITE-SYNTAX RowStatus { createAndGo(4), destroy(6) } DESCRIPTION "Support for notInService, createAndWait, and notReady is not required. " OBJECT teTunnelRowStatus SYNTAX RowStatus { active(1), notInService(2) } WRITE-SYNTAX RowStatus { active(1), notInService(2), createAndGo(4), destroy(6) } DESCRIPTION "Support for createAndWait and notReady is not required. " OBJECT teTunnelSourceAddressType DESCRIPTION "Write access is required. An implementation of a path computation server SHOULD support all types of tunnel source address types. " OBJECT tePathRowStatus SYNTAX RowStatus { active(1), notInService(2) } WRITE-SYNTAX RowStatus { active(1), notInService(2), createAndGo(4), destroy(6) } DESCRIPTION "Support for createAndWait and notReady is not required. " OBJECT tePathHopRowStatus Kompella Standards Track [Page 39] RFC 3970 A Traffic Engineering (TE) MIB January 2005 SYNTAX RowStatus { active(1), notInService(2) } WRITE-SYNTAX RowStatus { active(1), notInService(2), createAndGo(4), destroy(6) } DESCRIPTION "Support for createAndWait and notReady is not required. " ::= { teModuleCompliance 4 } END 6. References 6.1. Normative References [1] Bradner, S., "Key words for use in RFCs to Indicate Requirement Levels", BCP 14, RFC 2119, March 1997. [2] McCloghrie, K., Perkins, D., and J. Schoenwaelder, "Structure of Management Information Version 2 (SMIv2)", STD 58, RFC 2578, April 1999. [3] McCloghrie, K., Perkins, D., and J. Schoenwaelder, "Textual Conventions for SMIv2", STD 58, RFC 2579, April 1999. [4] McCloghrie, K., Perkins, D., and J. Schoenwaelder, "Conformance Statements for SMIv2", STD 58, RFC 2580, April 1999. [5] Nadeau, T. and J. Cucchiara, "Definitions of Textual Conventions (TCs) for Multiprotocol Label Switching (MPLS) Management", RFC 3811, June 2004. [6] Harrington, D., Presuhn, R., and B. Wijnen, "An Architecture for Describing Simple Network Management Protocol (SNMP) Management Frameworks", STD 62, RFC 3411, December 2002. [7] Awduche, D., Malcolm, J., Agogbua, J., O'Dell, M., and J. McManus, "Requirements for Traffic Engineering Over MPLS", RFC 2702, September 1999. 6.2. Informative References [8] Awduche, D., Berger, L., Gan, D., Li, T., Srinivasan, V., and G. Swallow, "RSVP-TE: Extensions to RSVP for LSP Tunnels", RFC 3209, December 2001. Kompella Standards Track [Page 40] RFC 3970 A Traffic Engineering (TE) MIB January 2005 [9] Case, J., Mundy, R., Partain, D., and B. Stewart, "Introduction and Applicability Statements for Internet-Standard Management Framework", RFC 3410, December 2002. [10] McCloghrie, K. and F. Kastenholz, "The Interfaces Group MIB", RFC 2863, June 2000. [11] Thaler, D., "IP Tunnel MIB", RFC 2667, August 1999. [12] Jamoussi, B., Andersson, L., Callon, R., Dantu, R., Wu, L., Doolan, P., Worster, T., Feldman, N., Fredette, A., Girish, M., Gray, E., Heinanen, J., Kilty, T., and A. Malis, "Constraint- Based LSP Setup using LDP", RFC 3212, January 2002. 7. Security Considerations This MIB module relates to the configuration and management of Traffic Engineering tunnels. The unauthorized manipulation of fields in the tables teAdminGroupTable, teTunnelTable, tePathTable, and tePathHopTable may lead to tunnel flapping, tunnel paths being changed, or traffic being disrupted. In addition, if these tables are read by unauthorized parties, the information can be used to trace traffic patterns, traffic volumes, and tunnel paths. This may be considered proprietary and confidential information by some providers. There are a number of management objects defined in this MIB module with a MAX-ACCESS clause of read-write and/or read-create. Such objects may be considered sensitive or vulnerable in some network environments. The support for SET operations in a non-secure environment without proper protection can have a negative effect on network operations. These are the tables and objects and their sensitivity/vulnerability: teAdminGroupTable: Changing this will affect the semantics of include and exclude constraints, and thus traffic takes unintended routes. teTunnelTable: Changing this affects many properties of traffic tunnels. tePathTable: Changing this affects the constraints (including bandwidth) of tunnel paths, as well as the status of the path. tePathHopTable: Changing this affects the route followed by a traffic tunnel path. Kompella Standards Track [Page 41] RFC 3970 A Traffic Engineering (TE) MIB January 2005 Some of the readable objects in this MIB module (i.e., objects with a MAX-ACCESS other than not-accessible) may be considered sensitive or vulnerable in some network environments. It is thus important to control even GET and/or NOTIFY access to these objects and possibly to even encrypt the values of these objects when sending them over the network via SNMP. These are the tables and objects and their sensitivity/vulnerability: teTunnelTable: Describes tunnel endpoints and traffic volumes. tePathTable: Describes path properties. tePathHopTable: Describes path routes. SNMP versions prior to SNMPv3 did not include adequate security. Even if the network itself is secure (for example by using IPSec), even then, there is no control as to who on the secure network is allowed to access and GET/SET (read/change/create/delete) the objects in this MIB module. It is RECOMMENDED that implementers consider the security features as provided by the SNMPv3 framework (see [9], section 8), including full support for the SNMPv3 cryptographic mechanisms (for authentication and privacy). Further, deployment of SNMP versions prior to SNMPv3 is NOT RECOMMENDED. Instead, it is RECOMMENDED to deploy SNMPv3 and to enable cryptographic security. It is then a customer/operator responsibility to ensure that the SNMP entity giving access to an instance of this MIB module is properly configured to give access to the objects only to those principals (users) that have legitimate rights to indeed GET or SET (change/create/delete) them. Acknowledgments It was Tony Li's suggestion that the author embark on this MIB. Many thanks to him and to Der-Hwa Gan for their input and help. Many thanks, too, to Bert Wijnen for his incredible help, both with improving the correctness, structure, and readability of the MIB module, and with the text of the RFC. Thanks also to Adrian Farrel for his detailed review. Kompella Standards Track [Page 42] RFC 3970 A Traffic Engineering (TE) MIB January 2005 Author's Address Kireeti Kompella Juniper Networks, Inc. 1194 N. Mathilda Ave Sunnyvale, CA 94089 EMail: kireeti@juniper.net Kompella Standards Track [Page 43] RFC 3970 A Traffic Engineering (TE) MIB January 2005 Full Copyright Statement Copyright (C) The Internet Society (2005). This document is subject to the rights, licenses and restrictions contained in BCP 78, and except as set forth therein, the authors retain all their rights. This document and the information contained herein are provided on an "AS IS" basis and THE CONTRIBUTOR, THE ORGANIZATION HE/SHE REPRESENTS OR IS SPONSORED BY (IF ANY), THE INTERNET SOCIETY AND THE INTERNET ENGINEERING TASK FORCE DISCLAIM ALL WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO ANY WARRANTY THAT THE USE OF THE INFORMATION HEREIN WILL NOT INFRINGE ANY RIGHTS OR ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Intellectual Property The IETF takes no position regarding the validity or scope of any Intellectual Property Rights or other rights that might be claimed to pertain to the implementation or use of the technology described in this document or the extent to which any license under such rights might or might not be available; nor does it represent that it has made any independent effort to identify any such rights. Information on the IETF's procedures with respect to rights in IETF Documents can be found in BCP 78 and BCP 79. Copies of IPR disclosures made to the IETF Secretariat and any assurances of licenses to be made available, or the result of an attempt made to obtain a general license or permission for the use of such proprietary rights by implementers or users of this specification can be obtained from the IETF on-line IPR repository at http://www.ietf.org/ipr. The IETF invites any interested party to bring to its attention any copyrights, patents or patent applications, or other proprietary rights that may cover technology that may be required to implement this standard. Please address the information to the IETF at ietf- ipr@ietf.org. Acknowledgement Funding for the RFC Editor function is currently provided by the Internet Society. Kompella Standards Track [Page 44]
RFC, FYI, BCP