Network Working Group C. DeSanti Request for Comments: 4983 H.K. Vivek Category: Standards Track K. McCloghrie Cisco Systems S. Gai Nuova Systems August 2007 Fibre Channel Registered State Change Notification (RSCN) MIB Status of This Memo This document specifies an Internet standards track protocol for the Internet community, and requests discussion and suggestions for improvements. Please refer to the current edition of the "Internet Official Protocol Standards" (STD 1) for the standardization state and status of this protocol. Distribution of this memo is unlimited. Abstract This memo defines a portion of the Management Information Base (MIB) for use with network management protocols in the Internet community. In particular, it describes managed objects for information related to the management of Fibre Channel's Registered State Change Notifications (RSCNs). DeSanti, et al. Standards Track [Page 1] RFC 4983 Fibre Channel RSCN MIB August 2007 Table of Contents 1. Introduction ....................................................3 2. The Internet-Standard Management Framework ......................3 3. Short Overview of Fibre Channel .................................3 4. Relationship to Other MIBs ......................................5 5. MIB Overview ....................................................5 5.1. Fibre Channel Management Instance ..........................5 5.2. Switch Index ...............................................6 5.3. Fabric Index ...............................................6 5.4. The t11FcRscnRegistrationGroup Group .......................6 5.5. The t11FcRscnNotifyGroup Group .............................6 5.6. The t11FcRscnNotifyControlGroup Group ......................7 5.7. The t11FcRscnStatsGroup Group ..............................7 6. Definitions .....................................................8 6.1. The T11-FC-RSCN-MIB Module .................................8 7. IANA Considerations ............................................23 8. Security Considerations ........................................24 9. Acknowledgements ...............................................25 10. Normative References ..........................................25 11. Informative References ........................................26 DeSanti, et al. Standards Track [Page 2] RFC 4983 Fibre Channel RSCN MIB August 2007 1. Introduction This memo defines a portion of the Management Information Base (MIB) for use with network management protocols in the Internet community. In particular, it describes managed objects for information related to Registered State Change Notifications (RSCNs) [FC-LS] in a Fibre Channel network, including which Nx_Ports are registered to receive which types of RSCNs, the control and generation of Simple Network Management Protocol (SNMP) notifications on registration failures, and RSCN-related statistics. This memo was previously approved by INternational Committee for Information Technology Standards (INCITS) Task Group T11.5 (http://www.t11.org); this document is a product of the IETF's IMSS working group. The key words "MUST", "MUST NOT", "REQUIRED", "SHALL", "SHALL NOT", "SHOULD", "SHOULD NOT", "RECOMMENDED", "MAY", and "OPTIONAL" in this document are to be interpreted as described in BCP 14, RFC 2119 [RFC2119]. 2. The Internet-Standard Management Framework For a detailed overview of the documents that describe the current Internet-Standard Management Framework, please refer to section 7 of RFC 3410 [RFC3410]. Managed objects are accessed via a virtual information store, termed the Management Information Base or MIB. MIB objects are generally accessed through the Simple Network Management Protocol (SNMP). Objects in the MIB are defined using the mechanisms defined in the Structure of Management Information (SMI). This memo specifies a MIB module that is compliant to the SMIv2, which is described in STD 58, RFC 2578 [RFC2578], STD 58, RFC 2579 [RFC2579] and STD 58, RFC 2580 [RFC2580]. 3. Short Overview of Fibre Channel The Fibre Channel (FC) is logically a bidirectional point-to-point serial data channel, structured for high performance. Fibre Channel provides a general transport vehicle for higher level protocols such as Small Computer System Interface (SCSI) command sets, the High- Performance Parallel Interface (HIPPI) data framing, IP (Internet Protocol), IEEE 802.2, and others. Physically, Fibre Channel is an interconnection of multiple communication points, called N_Ports, interconnected either by a switching network, called a Fabric, or by a point-to-point link. A DeSanti, et al. Standards Track [Page 3] RFC 4983 Fibre Channel RSCN MIB August 2007 Fibre Channel "node" consists of one or more N_Ports. A Fabric may consist of multiple Interconnect Elements, some of which are switches. An N_Port connects to the Fabric via a port on a switch called an F_Port. When multiple FC nodes are connected to a single port on a switch via an "Arbitrated Loop" topology, the switch port is called an FL_Port, and the nodes' ports are called NL_Ports. The term Nx_Port is used to refer to either an N_Port or an NL_Port. The term Fx_Port is used to refer to either an F_Port or an FL_Port. A switch port, which is interconnected to another switch port via an Inter-Switch Link (ISL), is called an E_Port. A B_Port connects a bridge device with an E_Port on a switch; a B_Port provides a subset of E_Port functionality. Many Fibre Channel components, including the fabric, each node, and most ports, have globally unique names. These globally unique names are typically formatted as World Wide Names (WWNs). More information on WWNs can be found in [FC-FS]. WWNs are expected to be persistent across agent and unit resets. Fibre Channel frames contain 24-bit address identifiers that identify the frame's source and destination ports. Each FC port has both an address identifier and a WWN. When a fabric is in use, the FC address identifiers are dynamically assigned by a switch. Each octet of a 24-bit address represents a level in an address hierarchy, with a Domain_ID being the highest level of the hierarchy. Registered State Change Notifications (RSCNs) are defined in [FC-LS] as a means to provide Nx_Ports that have registered to receive such notifications with a timely indication of changes in the state of nodes attached to the fabric. Specifically, an Nx_Port may choose to register, using a State Change Registration (SCR) request [FC-LS] to receive RSCNs. When an event occurs that may affect a registered Nx_Port's port's state, the registered Nx_Port will receive an RSCN. For example, an Nx_Port can use RSCNs as the means by which it is informed of the failures of other nodes, of new devices coming online, or even of more network-accessible storage becoming available. The payload of the RSCN indicates the type of change and includes the address of the changed port. RSCNs are often generated by the fabric, but an Nx_Port can also generate (and send to the fabric) an RSCN if and when it detects an event not visible to the fabric. The sender of an RSCN may coalesce several events into a single RSCN message. Each RSCN is a "request" that is acknowledged by the receiver with an accept or reject. An RSCN is received by an Nx_Port from the Fabric as an Extended Link Service (ELS) request [FC-LS]. The Fabric distributes RSCNs between Switches using an SW_ILS frame with an Inter-Switch RSCN payload, also known as an SW_RSCN [FC-SW-4]. So, when a Switch has directly DeSanti, et al. Standards Track [Page 4] RFC 4983 Fibre Channel RSCN MIB August 2007 attached Nx_Ports that have registered to receive RSCNs, it converts received SW_RSCNs (i.e., SW_ILS frames containing SW_RSCN payloads) into ELS requests containing the corresponding RSCN which it sends to each such Nx_Port. The latest standard for an interconnecting Fabric containing multiple Fabric Switch elements is [FC-SW-4]. [FC-SW-4] carries forward the earlier specification for the operation of a single Fabric in a physical infrastructure, and augments it with the definition of Virtual Fabrics and with the specification of how multiple Virtual Fabrics can operate within one (or more) physical infrastructures. The use of Virtual Fabrics provides for each frame to be tagged in its header to indicate which one of several Virtual Fabrics that frame is being transmitted on. All frames entering a particular "Core Switch" [FC-SW-4] (i.e., a physical switch) on the same Virtual Fabric are processed by the same "Virtual Switch" within that Core Switch. 4. Relationship to Other MIBs The first standardized MIB for Fibre Channel [RFC2837] was focused on Fibre Channel switches. It was replaced by the more generic Fibre Channel Management MIB [RFC4044] which defines basic information for Fibre Channel hosts and switches, including extensions to the standard [IF-MIB] for Fibre Channel interfaces. [RFC4044] includes the specification of how the generic objects defined in [IF-MIB] apply to Fibre Channel interfaces. This MIB imports some common Textual Conventions defined in the T11-TC-MIB [RFC4439] and in the T11-FC-NAME-SERVER-MIB [RFC4438]. 5. MIB Overview This section explains the use of a Fibre Channel management instance, a Switch Index, and a Fabric Index. It also describes the four MIB groups contained in the MIB. 5.1. Fibre Channel Management Instance A Fibre Channel management instance is defined in [RFC4044] as a separable managed instance of Fibre Channel functionality. Fibre Channel functionality may be grouped into Fibre Channel management instances in whatever way is most convenient for the implementation(s). For example, one such grouping accommodates a single SNMP agent having multiple AgentX [RFC2741] sub-agents, with each sub-agent implementing a different Fibre Channel management instance. DeSanti, et al. Standards Track [Page 5] RFC 4983 Fibre Channel RSCN MIB August 2007 The object, fcmInstanceIndex, is IMPORTed from the FC-MGMT-MIB [RFC4044] as the index value to uniquely identify each Fibre Channel management instance, for example, within the same SNMP context ([RFC3411], section 3.3.1). 5.2. Switch Index The FC-MGMT-MIB [RFC4044] defines the fcmSwitchTable as a table of information about Fibre Channel switches which are managed by Fibre Channel management instances. Each Fibre Channel management instance can manage one or more Fibre Channel switches. The Switch Index, fcmSwitchIndex, is IMPORTed from the FC-MGMT-MIB as the index value to uniquely identify a Fibre Channel switch amongst those (one or more) managed by the same Fibre Channel management instance. 5.3. Fabric Index Whether operating on a Physical Fabric (i.e., without Virtual Fabrics) or within a Virtual Fabric, the manner of operation of RSCNs within a/each Fabric is identical. Therefore, this MIB defines all Fabric-related information in tables that are INDEXed by an arbitrary integer, named a "Fabric Index", the syntax of which is IMPORTed from the T11-TC-MIB [RFC4439]. When a device is connected to a single Physical Fabric, without use of any Virtual Fabrics, the value of this Fabric Index will always be 1. In an environment of multiple Virtual and/or Physical Fabrics, this index provides a means to distinguish one Fabric from another. It is quite possible, and may even be likely, that a Fibre Channel switch will have ports connected to multiple Virtual and/or Physical Fabrics. Thus, in order to simplify a management protocol query concerning all the Fabrics to which a single switch is connected, fcmSwitchIndex will be listed before t11FcRscnFabricIndex when they both appear in the same INDEX clause. 5.4. The t11FcRscnRegistrationGroup Group This group contains information about the Nx_Ports which have registered to receive RSCNs. 5.5. The t11FcRscnNotifyGroup Group This group contains two notifications: one generated when a switch rejects an SCR or RSCN; the other when a switch rejects an SW_RSCN. DeSanti, et al. Standards Track [Page 6] RFC 4983 Fibre Channel RSCN MIB August 2007 5.5.1. Flow-Control for Notifications When defining SNMP notifications for events that occur in the data- plane, the maximum frequency of their generation needs to be considered. Unless there is some limiting factor, such notifications need to be flow-controlled in some way, e.g., defined such that after some maximum number within a specified time interval have occurred, further notifications are suppressed for some subsequent time interval. However, when such a suppression occurs, the Network Management System (NMS) that didn't receive the notifications (because they were suppressed) needs to be able to obtain an indication of how many were suppressed. Therefore, an additional Counter32 object needs to be defined, and/or a new type of notification needs to be defined for use at the end of the interval. While this is extra complexity, it is necessary for notifications that need to be flow-controlled. In contrast, for notifications such as both the ones defined in this MIB module, which are generated due to control-plane events (and are not able to start a chain reaction), the extra complexity of flow- controlling these types of notifications is not warranted. 5.6. The t11FcRscnNotifyControlGroup Group This group contains one object for each notification in the t11FcRscnNotifyGroup group to enable/disable that notification, as well as three objects that record information about the latest rejection of an SCR, RSCN or SW_RSCN. Specifically, they record the content (if available) of the rejected request, the source of the rejected request, and the reason for the rejection. 5.7. The t11FcRscnStatsGroup Group This group contains RSCN-related statistics. Two levels of statistics are included: 1) counters at the message-type level, for: - the number of SCRs received/rejected, - the number of RSCNs sent/received/rejected, - the number of SW_RSCNs sent/received/rejected. 2) counters for each different category of sent/received RSCNs, where different categories are indicated by different values of the 'Event Qualifier' contained in an RSCN message. Note that if and when several RSCN events are coalesced into a single RSCN message, then that message may be counted in more than one of these counters. No counters are defined in this MIB for the 'Event Qualifier' value of '0001'b (meaning "Changed Name DeSanti, et al. Standards Track [Page 7] RFC 4983 Fibre Channel RSCN MIB August 2007 Server Object") because these types of RSCNs are counted by the t11NsInRscns and t11NsOutRscns objects already defined in [RFC4438]. 6. Definitions 6.1. The T11-FC-RSCN-MIB Module T11-FC-RSCN-MIB DEFINITIONS ::= BEGIN -- The Fibre Channel RSCN MIB -- -- for the monitoring of registrations by Nx_Ports to receive -- Registered State Change Notifications (RSCNs), and the -- monitoring of RSCN usage. -- IMPORTS MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE, Counter32, mib-2 FROM SNMPv2-SMI -- [RFC2578] MODULE-COMPLIANCE, OBJECT-GROUP, NOTIFICATION-GROUP FROM SNMPv2-CONF -- [RFC2580] TruthValue FROM SNMPv2-TC -- [RFC2579] fcmInstanceIndex, fcmSwitchIndex, FcNameIdOrZero, FcAddressIdOrZero FROM FC-MGMT-MIB -- [RFC4044] T11NsGs4RejectReasonCode FROM T11-FC-NAME-SERVER-MIB -- [RFC4438] T11FabricIndex FROM T11-TC-MIB; -- [RFC4439] t11FcRscnMIB MODULE-IDENTITY LAST-UPDATED "200701080000Z" ORGANIZATION "For the initial versions, T11. For later versions, the IETF's IMSS Working Group." CONTACT-INFO " Claudio DeSanti Cisco Systems, Inc. 170 West Tasman Drive San Jose, CA 95134 USA EMail: cds@cisco.com Keith McCloghrie Cisco Systems, Inc. 170 West Tasman Drive San Jose, CA 95134 USA EMail: kzm@cisco.com" DESCRIPTION "The MIB module for the management of registrations DeSanti, et al. Standards Track [Page 8] RFC 4983 Fibre Channel RSCN MIB August 2007 by Nx_Ports to receive RSCNs (Registered State Change Notifications) on a Fibre Channel Fabric, as defined in FC-LS, and for the monitoring of RSCNs sent/received or rejected in a Fibre Channel Fabric. Copyright (C) The Internet Society (2007). This version of this MIB module is part of RFC 4983; see the RFC itself for full legal notices." REVISION "200701080000Z" DESCRIPTION "Initial version of this MIB module, published as RFC 4983." ::= { mib-2 161 } t11FcRscnNotifications OBJECT IDENTIFIER ::= { t11FcRscnMIB 0 } t11FcRscnObjects OBJECT IDENTIFIER ::= { t11FcRscnMIB 1 } t11FcRscnConformance OBJECT IDENTIFIER ::= { t11FcRscnMIB 2 } t11FcRscnRegistrations OBJECT IDENTIFIER ::= { t11FcRscnObjects 1 } t11FcRscnStats OBJECT IDENTIFIER ::= { t11FcRscnObjects 2 } t11FcRscnInformation OBJECT IDENTIFIER ::= { t11FcRscnObjects 3 } -- State Change Registration Table t11FcRscnRegTable OBJECT-TYPE SYNTAX SEQUENCE OF T11FcRscnRegEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table of Nx_Ports that have registered to receive RSCNs on all Fabrics configured on one or more Fibre Channel switches." ::= { t11FcRscnRegistrations 1 } t11FcRscnRegEntry OBJECT-TYPE SYNTAX T11FcRscnRegEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry containing information about one Nx_Port that has registered with a particular switch (identified by values of fcmInstanceIndex and fcmSwitchIndex) for a particular Fabric (identified by a t11FcRscnFabricIndex value)." INDEX { fcmInstanceIndex, fcmSwitchIndex, t11FcRscnFabricIndex, t11FcRscnRegFcId } ::= { t11FcRscnRegTable 1 } T11FcRscnRegEntry ::= SEQUENCE { DeSanti, et al. Standards Track [Page 9] RFC 4983 Fibre Channel RSCN MIB August 2007 t11FcRscnFabricIndex T11FabricIndex, t11FcRscnRegFcId FcAddressIdOrZero, t11FcRscnRegType BITS } t11FcRscnFabricIndex OBJECT-TYPE SYNTAX T11FabricIndex MAX-ACCESS not-accessible STATUS current DESCRIPTION "An index value that uniquely identifies a particular Fabric. In a Fabric conformant to FC-SW-4, multiple Virtual Fabrics can operate within one (or more) physical infrastructures. In such a case, this index value is used to uniquely identify a particular Fabric within a physical infrastructure. In a Fabric that has (or can have) only a single Fabric operating within the physical infrastructure, the value of this Fabric Index will always be 1." REFERENCE "ANSI INCITS 418-2006, Fibre Channel - Switch Fabric - 4 (FC-SW-4), December 2006." ::= { t11FcRscnRegEntry 1 } t11FcRscnRegFcId OBJECT-TYPE SYNTAX FcAddressIdOrZero (SIZE (3)) MAX-ACCESS not-accessible STATUS current DESCRIPTION "The Fibre Channel Address Identifier of the registering Nx_Port." ::= { t11FcRscnRegEntry 2 } t11FcRscnRegType OBJECT-TYPE SYNTAX BITS { fromFabricController(0), fromNxPort(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the type of registration desired by the registering Nx_Port, one bit per type: 'fromFabricController' -- RSCNs generated for events DeSanti, et al. Standards Track [Page 10] RFC 4983 Fibre Channel RSCN MIB August 2007 detected by the Fabric Controller. 'fromNxPorts' -- RSCNs generated for events detected by the affected Nx_Port." REFERENCE "ANSI INCITS 433-2007, Fibre Channel - Link Services (FC-LS), July 2007, Table 40." ::= { t11FcRscnRegEntry 3 } -- Statistics t11FcRscnStatsTable OBJECT-TYPE SYNTAX SEQUENCE OF T11FcRscnStatsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The RSCN-related statistics on all Fabrics configured on one or more Fibre Channel switches. Two levels of statistics are included: 1) counters at the message-type level, for: - the number of SCRs received/rejected, - the number of RSCNs sent/received/rejected, - the number of SW_RSCNs sent/received/rejected. 2) counters of sent/received RSCNs per 'Event Qualifier' value. Note that if and when several RSCN events are coalesced into a single RSCN message, then that message may be counted in more than one of these counters." ::= { t11FcRscnStats 1 } t11FcRscnStatsEntry OBJECT-TYPE SYNTAX T11FcRscnStatsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry containing statistics for a particular Fabric (identified by a t11FcRscnFabricIndex value) on a particular switch (identified by values of fcmInstanceIndex and fcmSwitchIndex)." INDEX { fcmInstanceIndex, fcmSwitchIndex, t11FcRscnFabricIndex } ::= { t11FcRscnStatsTable 1 } T11FcRscnStatsEntry ::= SEQUENCE { t11FcRscnInScrs Counter32, DeSanti, et al. Standards Track [Page 11] RFC 4983 Fibre Channel RSCN MIB August 2007 t11FcRscnInRscns Counter32, t11FcRscnOutRscns Counter32, t11FcRscnInSwRscns Counter32, t11FcRscnOutSwRscns Counter32, t11FcRscnScrRejects Counter32, t11FcRscnRscnRejects Counter32, t11FcRscnSwRscnRejects Counter32, t11FcRscnInUnspecifiedRscns Counter32, t11FcRscnOutUnspecifiedRscns Counter32, t11FcRscnInChangedAttribRscns Counter32, t11FcRscnOutChangedAttribRscns Counter32, t11FcRscnInChangedServiceRscns Counter32, t11FcRscnOutChangedServiceRscns Counter32, t11FcRscnInChangedSwitchRscns Counter32, t11FcRscnOutChangedSwitchRscns Counter32, t11FcRscnInRemovedRscns Counter32, t11FcRscnOutRemovedRscns Counter32 } t11FcRscnInScrs OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of SCRs received from Nx_Ports by this switch on this Fabric. This counter has no discontinuities other than those that all Counter32s have when sysUpTime=0." ::= { t11FcRscnStatsEntry 1 } t11FcRscnInRscns OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of RSCNs received from Nx_Ports by this switch on this Fabric. This counter has no discontinuities other than those that all Counter32s have when sysUpTime=0." ::= { t11FcRscnStatsEntry 2 } t11FcRscnOutRscns OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DeSanti, et al. Standards Track [Page 12] RFC 4983 Fibre Channel RSCN MIB August 2007 DESCRIPTION "The number of RSCNs transmitted to Nx_Ports by this switch on this Fabric. This counter has no discontinuities other than those that all Counter32s have when sysUpTime=0." ::= { t11FcRscnStatsEntry 3 } t11FcRscnInSwRscns OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of SW_RSCNs received by this switch from other switches on this Fabric. This counter has no discontinuities other than those that all Counter32s have when sysUpTime=0." ::= { t11FcRscnStatsEntry 4 } t11FcRscnOutSwRscns OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of SW_RSCNs transmitted by this switch from other switches on this Fabric. This counter has no discontinuities other than those that all Counter32s have when sysUpTime=0." ::= { t11FcRscnStatsEntry 5 } t11FcRscnScrRejects OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of SCRs rejected by this switch on this Fabric. This counter has no discontinuities other than those that all Counter32s have when sysUpTime=0." ::= { t11FcRscnStatsEntry 6 } t11FcRscnRscnRejects OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only DeSanti, et al. Standards Track [Page 13] RFC 4983 Fibre Channel RSCN MIB August 2007 STATUS current DESCRIPTION "The number of RSCNs rejected by this switch on this Fabric. This counter has no discontinuities other than those that all Counter32s have when sysUpTime=0." ::= { t11FcRscnStatsEntry 7 } t11FcRscnSwRscnRejects OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of SW_RSCN rejected by this switch on this Fabric. This counter has no discontinuities other than those that all Counter32s have when sysUpTime=0." ::= { t11FcRscnStatsEntry 8 } t11FcRscnInUnspecifiedRscns OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Registered State Change Notifications (RSCNs) received by this switch on this Fabric which contained an RSCN Event Qualifier value of '0000'b meaning 'Event is not specified'. This counter has no discontinuities other than those that all Counter32s have when sysUpTime=0." REFERENCE "ANSI INCITS 433-2007, Fibre Channel - Link Services (FC-LS), July 2007, Table 36." ::= { t11FcRscnStatsEntry 9 } t11FcRscnOutUnspecifiedRscns OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Registered State Change Notifications (RSCNs) sent by this switch on this Fabric which contained an RSCN Event Qualifier value of '0000'b meaning 'Event is not specified'. DeSanti, et al. Standards Track [Page 14] RFC 4983 Fibre Channel RSCN MIB August 2007 This counter has no discontinuities other than those that all Counter32s have when sysUpTime=0." REFERENCE "ANSI INCITS 433-2007, Fibre Channel - Link Services (FC-LS), July 2007, Table 36." ::= { t11FcRscnStatsEntry 10 } t11FcRscnInChangedAttribRscns OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Registered State Change Notifications (RSCNs) received by this switch on this Fabric which contained an RSCN Event Qualifier value of '0002'b meaning 'Changed Port Attribute'. This counter has no discontinuities other than those that all Counter32s have when sysUpTime=0." REFERENCE "ANSI INCITS 433-2007, Fibre Channel - Link Services (FC-LS), July 2007, Table 36." ::= { t11FcRscnStatsEntry 11 } t11FcRscnOutChangedAttribRscns OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Registered State Change Notifications (RSCNs) sent by this switch on this Fabric which contained an RSCN Event Qualifier value of '0002'b meaning 'Changed Port Attribute'. This counter has no discontinuities other than those that all Counter32s have when sysUpTime=0." REFERENCE "ANSI INCITS 433-2007, Fibre Channel - Link Services (FC-LS), July 2007, Table 36." ::= { t11FcRscnStatsEntry 12 } t11FcRscnInChangedServiceRscns OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Registered State Change Notifications (RSCNs) received by this switch on this Fabric which DeSanti, et al. Standards Track [Page 15] RFC 4983 Fibre Channel RSCN MIB August 2007 contained an RSCN Event Qualifier value of '0003'b meaning 'Changed Service Object'. This counter has no discontinuities other than those that all Counter32s have when sysUpTime=0." REFERENCE "ANSI INCITS 433-2007, Fibre Channel - Link Services (FC-LS), July 2007, Table 36." ::= { t11FcRscnStatsEntry 13 } t11FcRscnOutChangedServiceRscns OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Registered State Change Notifications (RSCNs) sent by this switch on this Fabric which contained an RSCN Event Qualifier value of '0003'b meaning 'Changed Service Object'. This counter has no discontinuities other than those that all Counter32s have when sysUpTime=0." REFERENCE "ANSI INCITS 433-2007, Fibre Channel - Link Services (FC-LS), July 2007, Table 36." ::= { t11FcRscnStatsEntry 14 } t11FcRscnInChangedSwitchRscns OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Registered State Change Notifications (RSCNs) received by this switch on this Fabric which contained an RSCN Event Qualifier value of '0004'b meaning 'Changed Switch Configuration'. This counter has no discontinuities other than those that all Counter32s have when sysUpTime=0." REFERENCE "ANSI INCITS 433-2007, Fibre Channel - Link Services (FC-LS), July 2007, Table 36." ::= { t11FcRscnStatsEntry 15 } t11FcRscnOutChangedSwitchRscns OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DeSanti, et al. Standards Track [Page 16] RFC 4983 Fibre Channel RSCN MIB August 2007 DESCRIPTION "The number of Registered State Change Notifications (RSCNs) sent by this switch on this Fabric which contained an RSCN Event Qualifier value of '0004'b meaning 'Changed Switch Configuration'. This counter has no discontinuities other than those that all Counter32s have when sysUpTime=0." REFERENCE "ANSI INCITS 433-2007, Fibre Channel - Link Services (FC-LS), July 2007, Table 36." ::= { t11FcRscnStatsEntry 16 } t11FcRscnInRemovedRscns OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Registered State Change Notifications (RSCNs) received by this switch on this Fabric which contained an RSCN Event Qualifier value of '0005'b meaning 'Removed Object'. This counter has no discontinuities other than those that all Counter32s have when sysUpTime=0." REFERENCE "ANSI INCITS 433-2007, Fibre Channel - Link Services (FC-LS), July 2007, Table 36." ::= { t11FcRscnStatsEntry 17 } t11FcRscnOutRemovedRscns OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Registered State Change Notifications (RSCNs) sent by this switch on this Fabric which contained an RSCN Event Qualifier value of '0005'b meaning 'Removed Object'. This counter has no discontinuities other than those that all Counter32s have when sysUpTime=0." REFERENCE "ANSI INCITS 433-2007, Fibre Channel - Link Services (FC-LS), July 2007, Table 36." ::= { t11FcRscnStatsEntry 18 } DeSanti, et al. Standards Track [Page 17] RFC 4983 Fibre Channel RSCN MIB August 2007 -- -- Notification Control Table -- t11FcRscnNotifyControlTable OBJECT-TYPE SYNTAX SEQUENCE OF T11FcRscnNotifyControlEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table of control information for notifications generated due to the rejection of an SCR or RSCN." ::= { t11FcRscnInformation 1 } t11FcRscnNotifyControlEntry OBJECT-TYPE SYNTAX T11FcRscnNotifyControlEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Each entry contains notification control information concerning the rejection of RSCN/SCRs for a particular Fabric (identified by the value of t11FcRscnFabricIndex) by a particular switch (identified by values of fcmInstanceIndex and fcmSwitchIndex)." INDEX { fcmInstanceIndex, fcmSwitchIndex, t11FcRscnFabricIndex } ::= { t11FcRscnNotifyControlTable 1 } T11FcRscnNotifyControlEntry ::= SEQUENCE { t11FcRscnIlsRejectNotifyEnable TruthValue, t11FcRscnElsRejectNotifyEnable TruthValue, t11FcRscnRejectedRequestString OCTET STRING, t11FcRscnRejectedRequestSource FcNameIdOrZero, t11FcRscnRejectReasonCode T11NsGs4RejectReasonCode, t11FcRscnRejectReasonCodeExp OCTET STRING, t11FcRscnRejectReasonVendorCode OCTET STRING } t11FcRscnIlsRejectNotifyEnable OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This object specifies if a t11FcRscnIlsRejectReqNotify notification should be generated when this switch rejects an SW_RSCN on this Fabric. Values written to this object should be retained over agent reboots." DEFVAL { false } ::= { t11FcRscnNotifyControlEntry 1 } DeSanti, et al. Standards Track [Page 18] RFC 4983 Fibre Channel RSCN MIB August 2007 t11FcRscnElsRejectNotifyEnable OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This object specifies if a t11FcRscnElsRejectReqNotify notification should be generated when this switch rejects an RSCN or SCR on this Fabric. Values written to this object should be retained over agent reboots." DEFVAL { false } ::= { t11FcRscnNotifyControlEntry 2 } t11FcRscnRejectedRequestString OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "The binary content of the RSCN, SCR, or SW_RSCN that was most recently rejected by this switch on this Fabric. The value is formatted as an octet string (in network byte order) as described in the relevant Fibre Channel standard, containing the payload (which is typically a list of affected ports and error codes) of the rejected RSCN or SCR as described in FC-LS, or the rejected SW_RSCN as described in FC-SW-4. This object contains the zero-length string if and when the RSCN/SCR/SW_RSCN payload is unavailable. When the length of this object is 255 octets, it contains the first 255 octets of the payload (in network byte order)." REFERENCE "ANSI INCITS 433-2007, Fibre Channel - Link Services (FC-LS), July 2007, Tables 34 & 39. ANSI INCITS 418-2006, Fibre Channel - Switch Fabric - 4 (FC-SW-4), December 2006, Table 45." ::= { t11FcRscnNotifyControlEntry 3 } t11FcRscnRejectedRequestSource OBJECT-TYPE SYNTAX FcNameIdOrZero MAX-ACCESS read-only STATUS current DESCRIPTION "The WWN that was the source of the RSCN, SCR, or SW_RSCN that was most recently rejected by this switch on this Fabric." DeSanti, et al. Standards Track [Page 19] RFC 4983 Fibre Channel RSCN MIB August 2007 ::= { t11FcRscnNotifyControlEntry 4 } t11FcRscnRejectReasonCode OBJECT-TYPE SYNTAX T11NsGs4RejectReasonCode MAX-ACCESS read-only STATUS current DESCRIPTION "This object contains the Reason Code of the most recent rejection by this switch of an RSCN, SCR or SW_RSCN on this Fabric." REFERENCE "ANSI INCITS 433-2007, Fibre Channel - Link Services (FC-LS), July 2007, Table 146. ANSI INCITS 418-2006, Fibre Channel - Switch Fabric - 4 (FC-SW-4), December 2006, Table 5." ::= { t11FcRscnNotifyControlEntry 5 } t11FcRscnRejectReasonCodeExp OBJECT-TYPE SYNTAX OCTET STRING (SIZE(1)) MAX-ACCESS read-only STATUS current DESCRIPTION "This object contains the Reason Code Explanation of the most recent rejection by this switch of an RSCN, SCR or SW_RSCN on this Fabric." REFERENCE "ANSI INCITS 433-2007, Fibre Channel - Link Services (FC-LS), July 2007, Table 147. ANSI INCITS 418-2006, Fibre Channel - Switch Fabric - 4 (FC-SW-4), December 2006, Table 6." ::= { t11FcRscnNotifyControlEntry 6 } t11FcRscnRejectReasonVendorCode OBJECT-TYPE SYNTAX OCTET STRING (SIZE(1)) MAX-ACCESS read-only STATUS current DESCRIPTION "This object contains the Reason Vendor Specific Code of the most recent rejection by this switch of an RSCN, SCR or SW_RSCN on this Fabric." REFERENCE "ANSI INCITS 433-2007, Fibre Channel - Link Services (FC-LS), July 2007, Table 148. ANSI INCITS 418-2006, Fibre Channel - Switch Fabric - 4 (FC-SW-4), December 2006, Section 6.1.3." DeSanti, et al. Standards Track [Page 20] RFC 4983 Fibre Channel RSCN MIB August 2007 ::= { t11FcRscnNotifyControlEntry 7 } -- Notifications t11FcRscnElsRejectReqNotify NOTIFICATION-TYPE OBJECTS { t11FcRscnRejectedRequestString, t11FcRscnRejectedRequestSource, t11FcRscnRejectReasonCode, t11FcRscnRejectReasonCodeExp, t11FcRscnRejectReasonVendorCode } STATUS current DESCRIPTION "This notification is generated when a switch rejects an SCR or RSCN. The value of t11FcRscnRejectedRequestString indicates the binary content of the rejected request if available, or the zero-length string otherwise. The source of the rejected request is given by t11FcRscnRejectedRequestSource, and the reason for rejection is given by the values of t11FcRscnRejectReasonCode, t11FcRscnRejectReasonCodeExp and t11FcRscnRejectReasonVendorCode." ::= { t11FcRscnNotifications 1 } t11FcRscnIlsRejectReqNotify NOTIFICATION-TYPE OBJECTS { t11FcRscnRejectedRequestString, t11FcRscnRejectedRequestSource, t11FcRscnRejectReasonCode, t11FcRscnRejectReasonCodeExp, t11FcRscnRejectReasonVendorCode } STATUS current DESCRIPTION "This notification is generated when a switch rejects an SW_RSCN. The value of t11FcRscnRejectedRequestString indicates the binary content of the rejected request if available, or the zero-length string otherwise. The source of the rejected request is given by t11FcRscnRejectedRequestSource, and the reason for rejection is given by the values of t11FcRscnRejectReasonCode, t11FcRscnRejectReasonCodeExp and t11FcRscnRejectReasonVendorCode." ::= { t11FcRscnNotifications 2 } -- Conformance t11FcRscnCompliances OBJECT IDENTIFIER ::= { t11FcRscnConformance 1 } t11FcRscnGroups OBJECT IDENTIFIER ::= { t11FcRscnConformance 2 } DeSanti, et al. Standards Track [Page 21] RFC 4983 Fibre Channel RSCN MIB August 2007 t11FcRscnCompliance MODULE-COMPLIANCE STATUS current DESCRIPTION "The compliance statement for entities that implement this MIB." MODULE MANDATORY-GROUPS { t11FcRscnRegistrationGroup, t11FcRscnNotifyControlGroup, t11FcRscnNotifyGroup } GROUP t11FcRscnStatsGroup DESCRIPTION "These counters, containing RSCN-related statistics, are mandatory only for those systems that count such events." OBJECT t11FcRscnIlsRejectNotifyEnable MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT t11FcRscnElsRejectNotifyEnable MIN-ACCESS read-only DESCRIPTION "Write access is not required." ::= { t11FcRscnCompliances 1 } -- Units of conformance t11FcRscnRegistrationGroup OBJECT-GROUP OBJECTS { t11FcRscnRegType } STATUS current DESCRIPTION "A collection of objects for monitoring RSCN registrations." ::= { t11FcRscnGroups 1 } t11FcRscnStatsGroup OBJECT-GROUP OBJECTS { t11FcRscnInScrs, t11FcRscnInRscns, t11FcRscnOutRscns, t11FcRscnInSwRscns, t11FcRscnOutSwRscns, t11FcRscnScrRejects, t11FcRscnRscnRejects, t11FcRscnSwRscnRejects, t11FcRscnInUnspecifiedRscns, DeSanti, et al. Standards Track [Page 22] RFC 4983 Fibre Channel RSCN MIB August 2007 t11FcRscnOutUnspecifiedRscns, t11FcRscnInChangedAttribRscns, t11FcRscnOutChangedAttribRscns, t11FcRscnInChangedServiceRscns, t11FcRscnOutChangedServiceRscns, t11FcRscnInChangedSwitchRscns, t11FcRscnOutChangedSwitchRscns, t11FcRscnInRemovedRscns, t11FcRscnOutRemovedRscns } STATUS current DESCRIPTION "A collection of objects for collecting RSCN-related statistics." ::= { t11FcRscnGroups 2 } t11FcRscnNotifyControlGroup OBJECT-GROUP OBJECTS { t11FcRscnIlsRejectNotifyEnable, t11FcRscnElsRejectNotifyEnable, t11FcRscnRejectedRequestString, t11FcRscnRejectedRequestSource, t11FcRscnRejectReasonCode, t11FcRscnRejectReasonCodeExp, t11FcRscnRejectReasonVendorCode } STATUS current DESCRIPTION "A collection of notification control and notification information objects." ::= { t11FcRscnGroups 3 } t11FcRscnNotifyGroup NOTIFICATION-GROUP NOTIFICATIONS { t11FcRscnIlsRejectReqNotify, t11FcRscnElsRejectReqNotify } STATUS current DESCRIPTION "A collection of notifications for monitoring ILS and ELS rejections by the RSCN module." ::= { t11FcRscnGroups 4 } END 7. IANA Considerations IANA has assigned a MIB OID for the T11-FC-RSCN-MIB module under the appropriate subtree. DeSanti, et al. Standards Track [Page 23] RFC 4983 Fibre Channel RSCN MIB August 2007 8. Security Considerations There are a number of management objects defined in this MIB module with a MAX-ACCESS clause of read-write and/or read-create. Such objects may be considered sensitive or vulnerable in some network environments. The support for SET operations in a non-secure environment without proper protection can have a negative effect on network operations. These objects and their sensitivity/vulnerability are: t11FcRscnIlsRejectNotifyEnable t11FcRscnElsRejectNotifyEnable -- ability to enable/disable a notification; these object, if misconfigured, would either generate unwanted notifications or suppress wanted notifications. Some of the readable objects in this MIB module (i.e., objects with a MAX-ACCESS other than not-accessible) may also be considered sensitive or vulnerable in some network environments. It is thus important to control even GET and/or NOTIFY access to these objects and possibly to even encrypt the values of these objects when sending them over the network via SNMP. These are the tables and objects and their sensitivity/vulnerability: t11FcRscnRegTable -- contains a list of Nx_Ports that are currently registered to received RSCNs. t11FcRscnStatsTable -- contains RSCN-related statistics. t11FcRscnNotifyControlTable -- contains control and logging information for notifications that are concerned with the rejection of RSCN-related requests. SNMP versions prior to SNMPv3 did not include adequate security. Even if the network itself is secure (for example by using IPsec), even then, there is no control as to who on the secure network is allowed to access and GET/SET (read/change/create/delete) the objects in this MIB module. It is RECOMMENDED that implementors consider the security features as provided by the SNMPv3 framework (see [RFC3410], section 8), including full support for the SNMPv3 cryptographic mechanisms (for authentication and privacy). Further, deployment of SNMP versions prior to SNMPv3 is NOT RECOMMENDED. Instead, it is RECOMMENDED to deploy SNMPv3 and to enable cryptographic security. It is then a customer/operator DeSanti, et al. Standards Track [Page 24] RFC 4983 Fibre Channel RSCN MIB August 2007 responsibility to ensure that the SNMP entity giving access to an instance of this MIB module is properly configured to give access to the objects only to those principals (users) that have legitimate rights to indeed GET or SET (change/create/delete) them. 9. Acknowledgements This document was originally developed and approved by the INCITS Task Group T11.5 (http://www.t11.org) as the SM-RSCNM project. We wish to acknowledge the many contributions and comments from the INCITS Technical Committee T11, especially from the following: T11 Chair: Robert Snively, Brocade T11 Vice Chair: Claudio DeSanti, Cisco Systems T11.5 Chair: Roger Cummings, Symantec T11.5 Vice Chair: Scott Kipp, McData and T11.5 members. The document was subsequently a work item of the IETF's IMSS Working Group, chaired by David Black (EMC Corporation). We thank Bert Wijnen (Lucent Technologies) for his thorough review of the document. We also wish to acknowledge Dan Romascanu (Avaya), the IETF Area Director, for his comments and assistance. 10. Normative References [RFC2578] McCloghrie, K., Perkins, D., Schoenwaelder, J., Case, J., Rose, M. and S. Waldbusser, "Structure of Management Information Version 2 (SMIv2)", STD 58, RFC 2578, April 1999. [RFC2579] McCloghrie, K., Perkins, D., Schoenwaelder, J., Case, J., Rose, M. and S. Waldbusser, "Textual Conventions for SMIv2", STD 58, RFC 2579, April 1999. [RFC2580] McCloghrie, K., Perkins, D., Schoenwaelder, J., Case, J., Rose, M. and S. Waldbusser, "Conformance Statements for SMIv2", STD 58, RFC 2580, April 1999. [RFC3411] Harrington, D., Presuhn, R., and B. Wijnen, "An Architecture for Describing Simple Network Management Protocol (SNMP) Management Frameworks", STD 58, RFC 3411, December 2002. [IF-MIB] McCloghrie, K. and F. Kastenholz, "The Interfaces Group MIB", RFC 2863, June 2000. DeSanti, et al. Standards Track [Page 25] RFC 4983 Fibre Channel RSCN MIB August 2007 [RFC4044] McCloghrie, K., "Fibre Channel Management MIB", RFC 4044, May 2005. [RFC4438] DeSanti, C., Gaonkar, V., Vivek, H.K., McCloghrie, K., and S. Gai, "Fibre Channel Name Server MIB", RFC 4438, March 2006. [RFC4439] DeSanti, C., Gaonkar, V., McCloghrie, K., and S. Gai, "Fibre Channel Fabric Address Manager MIB", RFC 4439, March 2006. [FC-SW-4] "Fibre Channel - Switch Fabric - 4 (FC-SW-4)", ANSI INCITS 418-2006, http://www.t11.org/t11/stat.nsf/upnum/1674-d, December 2006. [FC-FS] "Fibre Channel - Framing and Signaling (FC-FS)", ANSI INCITS 373-2003, http://www.t11.org/t11/stat.nsf/upnum/1331-d, April 2003. [FC-LS] "Fibre Channel - Link Services (FC-LS)", ANSI INCITS 433-2007, http://www.t11.org/t11/stat.nsf/upnum/1620-d, July 2007. [RFC2119] Bradner, S., "Key words for use in RFCs to Indicate Requirement Levels", BCP 14, RFC 2119, March 1997. 11. Informative References [RFC2741] Daniele, M., Wijnen, B., Ellison, M., and D. Francisco, "Agent Extensibility (AgentX) Protocol Version 1", RFC 2741, January 2000. [RFC2837] Teow, K., "Definitions of Managed Objects for the Fabric Element in Fibre Channel Standard", RFC 2837, May 2000. [RFC3410] Case, J., Mundy, R., Partain, D., and B. Stewart, "Introduction and Applicability Statements for Internet- Standard Management Framework", RFC 3410, December 2002. DeSanti, et al. Standards Track [Page 26] RFC 4983 Fibre Channel RSCN MIB August 2007 Authors' Addresses Claudio DeSanti Cisco Systems, Inc. 170 West Tasman Drive San Jose, CA 95134 USA Phone: +1 408 853-9172 EMail: cds@cisco.com H.K. Vivek Cisco Systems, Inc. 71 Millers Rd Bangalore, India Phone: +91 80 2289933x5117 EMail: hvivek@cisco.com Keith McCloghrie Cisco Systems, Inc. 170 West Tasman Drive San Jose, CA 95134 USA Phone: +1 408 526-5260 EMail: kzm@cisco.com Silvano Gai Nuova Systems 3 West Plumeria Drive San Jose, CA 95134 Phone: +1 408 387-6123 EMail: sgai@nuovasystems.com DeSanti, et al. Standards Track [Page 27] RFC 4983 Fibre Channel RSCN MIB August 2007 Full Copyright Statement Copyright (C) The IETF Trust (2007). This document is subject to the rights, licenses and restrictions contained in BCP 78, and except as set forth therein, the authors retain all their rights. This document and the information contained herein are provided on an "AS IS" basis and THE CONTRIBUTOR, THE ORGANIZATION HE/SHE REPRESENTS OR IS SPONSORED BY (IF ANY), THE INTERNET SOCIETY, THE IETF TRUST AND THE INTERNET ENGINEERING TASK FORCE DISCLAIM ALL WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO ANY WARRANTY THAT THE USE OF THE INFORMATION HEREIN WILL NOT INFRINGE ANY RIGHTS OR ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Intellectual Property The IETF takes no position regarding the validity or scope of any Intellectual Property Rights or other rights that might be claimed to pertain to the implementation or use of the technology described in this document or the extent to which any license under such rights might or might not be available; nor does it represent that it has made any independent effort to identify any such rights. Information on the procedures with respect to rights in RFC documents can be found in BCP 78 and BCP 79. Copies of IPR disclosures made to the IETF Secretariat and any assurances of licenses to be made available, or the result of an attempt made to obtain a general license or permission for the use of such proprietary rights by implementers or users of this specification can be obtained from the IETF on-line IPR repository at http://www.ietf.org/ipr. The IETF invites any interested party to bring to its attention any copyrights, patents or patent applications, or other proprietary rights that may cover technology that may be required to implement this standard. Please address the information to the IETF at ietf-ipr@ietf.org. DeSanti, et al. Standards Track [Page 28]
RFC, FYI, BCP